PUMP SYSTEMS Archives - Schaffert Mfg. Co.

Pump System & Components

FERTILIZER PUMP SYSTEMS

A Breakdown of the Components

The Schaffert liquid fertilizer distribution system is uniquely designed and assembled to meet the individual customer needs.

Preassembled Pump Stand

GX1 SINGLE PUMP & GX2 DOUBLE PUMP DISTRIBUTION CENTERS

Depending upon the size of the implement and the desired rate of application, systems can be either single or dual pump and are shipped 90% assembled.

The pump stand is predrilled for attachment to the implement bars or tongue (optional mount bracket required). Either system consists of the stand, pump(s), filters and manifold distribution components. Both systems are provided with two filters.

REMCO PUMP

The Schaffert Fertilizer Distribution System is powered by an American made, 12 volt REMCO pump.

The heavy duty motor is sealed with epoxy coating to resist fertilizer and chemical exposure. The pump has a five chamber construction that will handle up to 300 gallons per hour or 5.3 gallons of liquid per minute.

FILTERS

Fertilizer should enter the system through the 50 mesh filter housing, run through the pump(s) and proceed to the 80 mesh filter housing for discharge to the manifold. These caged filters are placed in directional housings.

Upon exiting the 80 mesh filter, the fertilizer is directed to the manifold distribution component.

The customer will need to reattach the manifold assembly to the main stand and connect the flow hose to the manifold. These three connections will complete the assembly of the pump(s) stand. (See Manifold Distribution Component.)

Electrical Connections

Wire connections (see image):

A: 12 Volt DC—Power connection to battery ONLY

B: Pump Cable Connection and/or “Y” Cable—Connection for dual pump systems

C: Remote Run Hold Whisker Switch Connection—DO NOT discard shorting plug after removal; retain for use should Run Hold switch get damaged

MANX CONNECTIONS

We have had a special 12volt/25 amp speed controller designed. The Man-X Controller will handle the load of a single pump or two 12 volt pumps simultaneously for the larger planters and drills on the market.

On the front of the Man-X Controller is the main on/off switch plus a control knob used to increase or decrease motor speed, thereby changing the pressure within the system.

The preferred installation of the Man-X Controller is in the cab of the tractor with the provided fused power cable connected to the tractor battery and NOT to an accessory plug. This method allows for the proper amperage draw by the motor(s).

Other connections to the Man-X Controller are for the power cable(s) to the pump(s) and the remotely mounted Run Hold Switch.

Should you have a system that requires dual pumps, a provided “Y” cable is plugged into the controller pump lead and the two pump power cables are plugged into the “Y” cable.

The main power switch of the Man-X controller is on the face of the unit.

MAGMOUNT & RUN HOLD SWITCH

The Run Hold Switch and its magnetic mounted bracket (Magmount) also plug into the Man-X Controller. These connections are described in the instruction sheet included with the Man-X Controller.

The Run Hold switch and its magnetically mounted bracket is positioned near the lift arms of the 3 point hitch or the lift wheels of the planter. With the main power switch on and the Remote Run Hold switch connected, the pump(s) will operate when the planter is in the ground and off when lifted.

The whisker wire in the straight position (as shipped) is closed for normal operation. When the whisker is bent, power is interrupted and the pump(s) operation ceases.

The 100 pound pull magnet/bracket allows multiple positioning options for you to choose. We advise you tether the Magmount to your planter.

Manifold Distribution Component

MANIFOLD OPTIONS

Two types of manifolds are offered to the customer.

Both the PVC piping system and the visual Wilger columns are designed to insure that equal amounts of product are provided to each row.

This is accomplished by placing the properly sized orifice in the top of each manifold outlet.

Orifice selection charts and installation guidelines are provided separately.

The individual row unit lines are either 1/4″ OD tubing (less than 10gpa) or 3/8″ OD tubing depending upon the customer application needs.

Colored disc (top) and Wilger (bottom) orifices

APPLICATION RATE

This pressure in combination with properly selected orifices, ground speed, fertilizer weight and row spacing will determine the rate of application.

With the rate chart provided with each system, one can select the proper pressure and orifice for the desired gallons per acre (gpa).

The type of orifice used will also depend on the chosen manifold setup. The colored disc orifices are used with the PVC manifold. The Wilger orifices are used with the Wilger columns.

CHECK VALVES

A 5 pound check valve is provided for each line.

The check valve will close with loss of pressure from the pump(s) shutting off and liquid will remain in the system, keeping it fully charged until planting is resumed. A small amount of fertilizer will be lost from the check valve down to the row unit.

For this reason, it is advised that the valve be placed as near the discharge site as possible, but still remain accessible should difficulties arise.

The Check Valves are directional and connect in the same manner as the Quick Connects (see next).

Press ring (shown in red) to release hose

QUICK CONNECT

he tops of the manifold are terminated with a Quick Coupler (QC). This device makes it very easy to connect your line hoses.

These couplers act as a “Chinese Finger”, in that once the hoses are inserted they cannot be easily removed. HOWEVER, should you need to remove a hose, simply hold the ring of the coupler next to the body of the fitting with your fingernail or pocket knife. This will release the pressure against the hose. Then give a light pull on the hose for removal.

It is important that prior to inserting the hose into the QC, the hose have a square cut end, as it must seat against an O ring inside the coupler.

GAUGE

A 60 pound stainless steel gauge is included and may be mounted either directly on the manifold tee fitting or remotely, using a magnetic bracket.

Off-Season Care

Upon the completion of planting season, we highly recommend that the entire fertilizer distribution system be flushed out with clean water.

Fertilizer will eventually crystallize and can cause damage to components of the system if this step is ignored. Many customers will recharge and then drain the system prior to storage, and then store it with Recreational Vehicle (RV) antifreeze.

DOSATRON®

In-Furrow Direct Injection Kit

The Dosatron is made to work with fungicides and insecticides.

About the Dosatron

Apply fungicide and insecticide in-furrow along with starter without premixing in a single tank.

The Dosatron® direct injection kit is designed to be a simple cost effective way to apply fungicide and insecticide in-furrow with the seed.

Benefits of the Dosatron

Dosatron and GX2 with GPS
  • The Dosatron pump operates off the volume flow of your starter fertilizer and requires no electricity or agitation during application
  • Can go from 0-36 ounces per minute with the turn of a knob
  • Can be easily mounted onto your planter or with our pumps
  • Includes a 10-gallon tank
  • Optional Xanthion™ agitation kits available
Dosatron with GX2 and GX1 distribution centers

FERTILIZER APPLICATION RATE CHARTS

DO NOT run orifices with squeeze pumps. This cannot be done because squeeze pumps do not put out enough pressure for an orifice system. Squeeze pumps only put out 2-3 pounds of pressure.

Colored Disc Orifice

NEW High Pressure Injector Orifice

Schaffert Mfg.’s new high pressure injector orifice is made to screw into the high pressure kit for our 2×2 fertilizer disc (G2) and 2×2 fertilizer tube (for Case IH).

These 2×2 systems work well with Schaffert’s pump systems.

orifices-injector
Orifice end (left) and hex end (right)

Features of the orifice include:

  • Screws inside 3/8″ stainless tube
  • Easy to install with an Allen wrench
  • Orifice OD is 5/16″
  • Stainless steel compact design
  • 10 color coated orifice sizes
  • Injects high pressure, 2-40 GPA
  • Universal models – fits many machines
  • Allows tube to be closer to soil surface, eliminating trash buildup

To find the correct injector orifice for your high pressure kit, you will need to know:

  • Number of rows
  • Row spacing
  • Travel speed
  • Pressure
  • Kind of fertilizer
  • Product weight
  • Gallons per acre

PLEASE NOTE: We normally recommend using only 1 orifice under pressure when running 7-15 lbs of pressure. However, using 2 orifices under pressure can be beneficial because it will help eliminate fertilizer splatter or misting/volatilization of fertilizer when done in the following manner:

  • Use the correct size orifice above for 15-30 psi pressures
  • Use 2-3 times size orifice below, creating 5-7 lbs pressure to stream fertilizer into the soil

NEVER USE 2 OF THE SAME SIZE ORIFICES IN YOUR SYSTEM!!!

DO NOT run orifices with squeeze pumps. This cannot be done because squeeze pumps do not put out enough pressure for an orifice system. Squeeze pumps only put out 2-3 pounds of pressure.

Wilger

  Wilger orifice chart calculated for 30″ rows

orifices-wilger

Other Rates

For other rates, please contact us.

PUMP SYSTEMS

For liquid fertilizer application

Looking for a fertilizer application system that works for your planter or drill? Let us help with a solution that fits your needs, requirements and budget.

Our customized Schaffert Mfg. single and dual pump systems offer everything you need.

About Our Pump Systems

gx2
gx1

The Schaffert fertilizer application system is uniquely designed and assembled to meet individual customer needs.

At the heart of our pump systems are the GX1 and GX2 distribution centers. The GX1 contains a single pump and the GX2 has dual pumps. The number of pumps needed is determined by the implement’s size and desired fertilizer application rate.

Our application kit options include:

  • 1-5# check valve per row (Wilger manifold with 1 set of orifices)
  • PVC pipe manifolds
  • 3 sets of orifices
  • 2 filters with 50 and 80 mesh screens
  • All 3/4″ and 1/4″ hose needed
  • One pump on 4-12 row systems or dual pumps on 16-48 row systems
  • 1 full port ball valve
  • Clean outs, wiring harnesses and all weather pack fittings
  • 0-60 PSI SS gauge
  • Run Hold switch with magnetic holder
  • Manual rate controller with 1 year warranty and reverse polarity protection
  • For photos and more information, see system components
manx-gauge-pump
ManX controller, Magmount pressure gauge, 5.3 GPM REMCO pump
pump-system-white
Pump system on a White planter

Schaffert Mfg.’s innovative planting attachments compliment these pump systems. Use the Rebounder Seed Covers with optional fittings for in-furrow application or our 2×2 fertilizer solutions for high volume output.

  Call 800-382-2607 or 308-364-2607 for a FREE quote

Benefits of Our Pump Systems

Features—Benefits

  • Complete pump system customized to your needs
  • Hassle free assembly
  • Pre-built tower so you can bolt on and go
  • Visualize your flow with optional Wilger columns
  • Easy adjust controller
  • Compatible with our Rebounder Seed Covers for in-furrow application and with your 2×2 fertilizer solutions for higher output nitrogen
  • Made in the USA

Standard kits include:

  • Pump(s) & filter
  • Manifold & distribution center
  • Fertilizer placement options
  • Controller & wiring harnesses
  • Automatic shut-off
tower-assembling
We do 90% of the assembly
tower-assembling-2
8row-dual-pump

Testimonials